American Fireglass SS-H-30 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
Burner Pan
4.00”
Optional Valve mounting location
AFLMF Valve Kit
2.0” Min.
2.0” Min.
2.0” Min.
2.0” Min.
Burner Pan
Basket Grate
Burner Pan
Basket Grate
4.0”
4.0”
Optional pilot mounting location
Pilot monting location
AFLMF Valve Kit
Optional Valve mounting location
Figure #1
Figure #2
Figure #4
CONNECTING THE REMOTE CONTROL ON AF-LMF/R & AF-LMF/RD & AF-LMF-RVS VALVE KITS
The remote control receiver is to be placed next to the valve kit, away from the re (Note: Figure #5).1.
Remove receiver shield and battery cover then install (4) AA alkaline batteries. Reinstall receiver shield.2.
Connect the red and black wires from the ON/OFF latching solenoid on the valve to the red and black wires from the remote re-3.
ceiver. If installing the AF-LMF-RVS connect the 4-pin connector from the step motor to the remote receiver (Figure #6).
Refer to the4. instructions supplied with the remote control for operation of the remote control.
Burner Pan
Basket Grate
AFLMF Valve Kit
AFLMF Valve Kit
RCAF-LMF
Remote Control
Receiver
RCAF-LMF
Remote Control
Receiver
Figure #5
Figure #6
LIGHTING & SHUT OFF PROCEDURES
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
This product has a standing pilot, which must be lit by hand. When lighting the pilot, follow these instructions exactly.
This product should be installed including provisions for combustion and ventilation air, must conform with local codes or, in the
absence of local codes, to the National Fuel Gas Code, ANSI Z223 latest addition.
This product must be on a gas supply line that is less than 1/2 psi. and with an individual manual shut off.
Never operate this new system with the glass replace enclosures (doors) in the closed position.
Connecting 110-volt electrical power to this product will cause damage and will void warranty.
PILOT GAS AND LIGHTING PROCEDURE
Turn the gas control knob counterclockwise to the 1. PILOT position, push the gas control knob IN and HOLD in position. This will
open the pilot valve and allows gas to ow to the pilot burner.
Light the pilot burner while holding the gas control knob in until a strong pilot ame is present. (Approximately 60-seconds)2.
Release the gas control knob and verify the pilot ame remains lit.3.
Turn the gas control knob counter clockwise to the 4. ON position, The main burner valve will open and the main burner will ignite,
SHUT OFF PROCEDURE
To shut 1. OFF the main burner while leaving the pilot ON, turn the gas control knob clockwise to the PILOT position. This action will
close the main gas ow.
To shut 2. OFF the main burner and pilot, turn the gas control knob clockwise to the OFF position. This action will close the main gas
valve and disengages the safety pilot valve. However the power unit must drop out before the lighting sequence can begin again.
This may take as long as 3 minutes.
To relight the pilot, follow the steps in the Pilot Gas and Lighting Procedure section.3.
REV 1-31-12 Page 3
American Flame AF-LMF Valve Kits
Flat 4 Wire with
4 pin Female
Connector
Flat 4 Wire with
4 pin Male
Connector
Receiver Back
Flat 4 Wire with
4 pin Female
Connector
Flat 4 Wire with
4 pin Male
Connector
AFLMF